mirror of
https://github.com/andreili/klipper.git
synced 2025-08-23 19:34:06 +02:00
docs: BED_MESH_CALIBRATE makes a mesh that is immediately available. (#6919)
The docs aren't particularly clear that if you generate a mesh in our start g-code, you can just use it without additional commands. This is causing issues with support on r/klippers Signed-off-by: Rowland Straylight <rowlandstraylight@gmail.com>
This commit is contained in:
parent
ed36041b67
commit
82f540bb73
@ -497,7 +497,8 @@ _Default Adaptive Margin: 0_
|
||||
|
||||
Initiates the probing procedure for Bed Mesh Calibration.
|
||||
|
||||
The mesh will be saved into a profile specified by the `PROFILE` parameter,
|
||||
The mesh will be immediately ready to use when the command completes and saved
|
||||
into a profile specified by the `PROFILE` parameter,
|
||||
or `default` if unspecified. The `METHOD` parameter takes one of the following
|
||||
values:
|
||||
|
||||
@ -561,6 +562,10 @@ load the `default` profile it is recommended to add
|
||||
`BED_MESH_PROFILE LOAD=default` to either their `START_PRINT` macro or their
|
||||
slicer's "Start G-Code" configuration, whichever is applicable.
|
||||
|
||||
Note that this is not required if a new mesh is generated with
|
||||
`BED_MESH_CALIBRATE` in the `START_PRINT` macro or the slicer's "Start G-Code"
|
||||
and may produce unexpected results, especially with adaptive meshing.
|
||||
|
||||
Alternatively the old behavior of loading a profile at startup can be
|
||||
restored with a `[delayed_gcode]`:
|
||||
|
||||
|
@ -174,8 +174,10 @@ The following commands are available when the
|
||||
[ADAPTIVE_MARGIN=<value>]`: This command probes the bed using generated points
|
||||
specified by the parameters in the config. After probing, a mesh is generated
|
||||
and z-movement is adjusted according to the mesh.
|
||||
The mesh is immediately active after successful completion of `BED_MESH_CALIBRATE`.
|
||||
The mesh will be saved into a profile specified by the `PROFILE` parameter,
|
||||
or `default` if unspecified.
|
||||
or `default` if unspecified. If ADAPTIVE=1 is specified then the profile
|
||||
name will begin with `adaptive-` and should not be saved for reuse.
|
||||
See the PROBE command for details on the optional probe parameters. If
|
||||
METHOD=manual is specified then the manual probing tool is activated - see the
|
||||
MANUAL_PROBE command above for details on the additional commands available
|
||||
|
Loading…
x
Reference in New Issue
Block a user